CD/EUR-36L EX DT (MFS) ULPA WITH SS CART 
  
 
  
    For the Pharma/Food Processing Industries - Manual Filter Shaker 
  
 
 
    
      Certifications
 
      
      
        
          | 
              
      
              
              
                
                | 
                    
                      |  | CD-EX Models Certified for: CLEANING MACHINES For Hazardous Locations (Classes C1618 01 & C1618 81) Class I, Division 1, Group D and Class II, Division 1, Groups F and G, T3CClass II, Division 1, Group E (metal dust) motor and switch available
 Class I, Division 2, Group D and Class II, Division 2, Groups F and G, T3C
 |  |  
                
                | 
                    
                      |  | CD EX Series IECEx 3rd Party CertifiedExternal: Ex db h IIB T4 Gb Ex h tb IIIC T135°C Db IP65
 Internal: Ex h IIC T6 Ga Ex h IIIC T50°C Da
 IECEx LCI 10.0040X
 |  |  
                
                | 
                    
                      |  | GUARANTEED for the Safe Recovery of Combustible/Conductive Dusts |  |  
                
                | 
                    
                      |  | ESD Safe Vacuum System designed to prevent Electrostatic Discharges (ESD) |  |  
                
                | 
                    
                      |  | Complies with NFPA 77 "Recommended Practice on Static Electricity" |  |  
                |  |  | 
 
      
 
      
      
 
 
 
      Features
 
      
      
        
          | 
              
      
              
              
              Legally certified explosion proof/dust ignition proof
              
      
              
              
              Less than 10 ohms of resistivity
              
      
              
              
              Continuous duty single phase or 3-phase (TEFC) explosion proof/dust ignition proof motor
              
      
              
              
              ULPA filter with an efficiency of 99.999% at 0.12 micron. Filtration efficiency of 99.9995% at 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822. All of our ULPA vacuum systems are aerosol leak tested before leaving our facility - included
              
      
              
              
              HEPA filter with an efficiency of 99.995% at 0.3 micron. Tested IEST-RP-CC001. H14 by MPPS method as per EN 1822 and OSHA compliant. All of our HEPA vacuum systems are aerosol leak tested before leaving our facility - included
              
      
              
              
              Muffler assembly, made of stainless steel with sound insulating foam to ensure quiet operation, is included
              
      
              
              
              Cleanroom compatible with ISO Class 4 (former Class 10). Can be used in the Pharmaceutical industry
              
      
              
              
              Manual Filter Shaker (MFS) system
              
      
              
              
              Static dissipative washable main filter is contained within a removable filter chamber
              
      
              
              
              All stainless steel Type 304 construction
              
      
              
              
              Detachable recovery tank (DT) for easy disposal of recovered materials
              
      
              
              
              Static dissipative poly liner and clip for the easy and safe disposal of recovered materials - available
              
      
              
              
              Vertical mounting for areas with space constraints
              
      
              
              
              Equipped with a Carriage with Suspended Motor Top (CSMT) and tool basket. Includes static dissipative wheels
              
      
              
              
              Optional Ø1.5" (Ø38 mm) or Ø2" (Ø50 mm) tools & accessories
              
      
              
              
              Motor and switch for use in the presence of conductive metal dust is available.
North-America: Class II, Group E
Europe: Dust Group IIIC
              
      
              
              
              Other motor performances available
              
       | 
 
      
 
      
      
     
 
    
    
 
    
       
     
 
    
      
Technical Specs - North America
 
    
 
    
 
    
    
 
    
      
      
      | Specifications | 112147A1-SS | 112147A2-SS | 112147A5-SS | 112148A3-SS | 112149A3-SS | 112150A1-SS | 
| Model Name | CD/EUR-36L EX DT (MFS) ULPA WITH SS CART - CLASS I - GROUP D, CLASS II - GROUPS F & G | CD/EUR-36L EX DT (MFS) ULPA WITH SS CART - CLASS I - GROUP D, CLASS II - GROUPS F & G | CD/EUR-36L EX DT (MFS) ULPA WITH SS CART - CLASS I - GROUP D, CLASS II - GROUPS F & G | CD/EUR-36L EX DT (MFS) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS F & G | CD/EUR-36L EX DT (MFS) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS E, F & G | CD/EUR-36L EX DT (MFS) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS E, F & G | 
| Type | Electric | Electric | Electric | Electric | Electric | Electric | 
| TEFC Motor | Yes | Yes | Yes | Yes | Yes | Yes | 
| Tension | 460 V | 230 V | 575 V | 120 V | 120 V | 460 V | 
| Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 
| Phase | Three | Three | Three | Single | Single | Three | 
| Wattage | 1480 W | 1480 W | 1480 W | 1110 W | 1110 W | 1480 W | 
| Power | 2 HP | 2 HP | 2 HP | 1.5 HP | 1.5 HP | 2 HP | 
| Amperage | 2.6 A | 5.2 A | 2.1 A | 15 A | 15 A | 2.6 A | 
| Air Flow | 158 CFM | 158 CFM | 158 CFM | 125 CFM | 125 CFM | 158 CFM | 
| Vacuum Pressure | 130 " H20 | 130 " H20 | 130 " H20 | 120 " H20 | 120 " H20 | 130 " H20 | 
| VRV Setting | 80 " H20 | 80 " H20 | 80 " H20 | 80 " H20 | 80 " H20 | 80 " H20 | 
| Sound Level when equipped with Silencer | 72 db(A) | 72 db(A) | 72 db(A) | 72 db(A) | 72 db(A) | 72 db(A) | 
| Type of Power Outlet | Not Included | Not Included | Not Included | Not Included | Not Included | Not Included | 
| Suction Inlet Port | 2 " | 2 " | 2 " | 2 " | 2 " | 2 " | 
| Cart Type | Detachable Tank (DT) | Detachable Tank (DT) | Detachable Tank (DT) | Detachable Tank (DT) | Detachable Tank (DT) | Detachable Tank (DT) | 
| Filter Cleaning | Manual Filter Shaker (MFS) | Manual Filter Shaker (MFS) | Manual Filter Shaker (MFS) | Manual Filter Shaker (MFS) | Manual Filter Shaker (MFS) | Manual Filter Shaker (MFS) | 
| Dust Recovery Tank | 9.5 Gal | 9.5 Gal | 9.5 Gal | 9.5 Gal | 9.5 Gal | 9.5 Gal | 
| Length | 30 " | 30 " | 30 " | 30 " | 30 " | 30 " | 
| Width | 24 " | 24 " | 24 " | 24 " | 24 " | 24 " | 
| Height | 75 " | 75 " | 75 " | 75 " | 75 " | 75 " | 
| Weight (Vacuum Only) | 249 lb. | 249 lb. | 249 lb. | 249 lb. | 249 lb. | 249 lb. | 
| Cord Length | 50 ft. | 50 ft. | 50 ft. | 50 ft. | 50 ft. | 50 ft. | 
| Star Shaped Main Filter Surface Area | 9.25 ft2 | 9.25 ft2 | 9.25 ft2 | 9.25 ft2 | 9.25 ft2 | 9.25 ft2 | 
| Specifications | 112150A2-SS | 112150A5-SS | 
| Model Name | CD/EUR-36L EX DT (MFS) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS E, F & G | CD/EUR-36L EX DT (MFS) ULPA WITH SS CART CLASS I - GROUP D, CLASS II - GROUPS E, F & G | 
| Type | Electric | Electric | 
| TEFC Motor | Yes | Yes | 
| Tension | 230 V | 575 V | 
| Frequency | 60 Hz | 60 Hz | 
| Phase | Three | Three | 
| Wattage | 1480 W | 1480 W | 
| Power | 2 HP | 2 HP | 
| Amperage | 5.2 A | 2.1 A | 
| Air Flow | 158 CFM | 158 CFM | 
| Vacuum Pressure | 130 " H20 | 130 " H20 | 
| VRV Setting | 80 " H20 | 80 " H20 | 
| Sound Level when equipped with Silencer | 72 db(A) | 72 db(A) | 
| Type of Power Outlet | Not Included | Not Included | 
| Suction Inlet Port | 2 " | 2 " | 
| Cart Type | Detachable Tank (DT) | Detachable Tank (DT) | 
| Filter Cleaning | Manual Filter Shaker (MFS) | Manual Filter Shaker (MFS) | 
| Dust Recovery Tank | 9.5 Gal | 9.5 Gal | 
| Length | 30 " | 30 " | 
| Width | 24 " | 24 " | 
| Height | 75 " | 75 " | 
| Weight (Vacuum Only) | 249 lb. | 249 lb. | 
| Cord Length | 50 ft. | 50 ft. | 
| Star Shaped Main Filter Surface Area | 9.25 ft2 | 9.25 ft2 | 
|
 
      
        Please note that specifications are subject to change without notice